Precautions when handling TAKIRON “IVY-ONE”
1 "IVY-ONE" includes glass fiber.
  • When cutting or drilling, always wear protective glasses or goggles and a face mask which covers the face and mouth. Itching due to glass fibers may be avoided by the use of abarrier creams on exposed skin areas.
2 Precautions when using TAKIRON "IVY-ONE"
  • When using TAKIRON "IVY-ONE", adequately identify the temperature requirements, type of cleaning solution, irradiation settings for ultraviolet rays, external stress such as furring, and other service conditions, and implement proper design and panel cutting.
  • For design and panel cutting, take into consideration the empirical approaches for fabrication.
  • The physical properties, chemical resistances, and other evaluation data contained in this site are typical test measurement values and given here without guarantee. Apply the data giving careful consideration to the actual application and service requirements.
  • Keep TAKIRON "IVY-ONE" away from contact with any plasticizer-containing soft PVC, rubber materials, thinner,or other materials with the capability to dissolve PVC, to prevent possible dissolved contact surfaces, roughened surface conditions, and other defects.
3 Precautions when fabricating TAKIRON "IVY-ONE"
  • TAKIRON "IVY-ONE" contains PE (polyethylene) protective film attached to both sides. Remember to remove the protective film prior to construction or use.
  • For fabrication of TAKIRON "IVY-ONE", wear proper gloves, safety goggles, and other protective equipment as required, and use proper machinery and tools.
  • TAKIRON "IVY-ONE" is a PVC product. PVC emits HCl gas when heated. Although this HCl gas does not attain a concentration that can affect the human body during normal welding work, HCl gas concentration can vary greatly with working space and hours, when the work is performed in an enclosed space. In particular, pay special attention when the work is performed in a confined environment. For welding processes involving PVC, secure safety by ensuring proper ventilation on a regular basis, and wearing a proper maskand other protective equipment.
4 Precautions when storing and transporting TAKIRON "IVY-ONE"
  • TAKIRON "IVY-ONE" can become curved or otherwise deformed when left tilted. Be sure to place wall panels on a horizontal surface for storage and transportation.
  • Remember that masking tape for TAKIRON "IVY-ONE" cannot be completely removed when they get wet in the rain or with water.
  • Avoid storing or transporting TAKIRON "IVY-ONE" and its fabricated products under direct sunlight or at elevated temperatures.
5 Precautions when disposing of TAKIRON "IVY-ONE"
  • TAKIRON "IVY-ONE" can emit harmful gases when incinerated. Refer to a designated industrial waste treatment company for the disposition of waste wall panels as industrial waste, in accordance with applicable laws and regulations.
* An FM Label is required to provide evidence that the concerned product is FM certified, and to ensure traceability in the event of any problem. Remember to keep FM Labels at hand.