| 1 |
"IVY-ONE" includes
glass fiber. |
- When cutting or drilling, always wear protective glasses or goggles and a face mask which covers the face and mouth.
Itching due to glass fibers may be avoided by the use of abarrier creams on exposed skin areas.
|
| 2 |
Precautions
when using TAKIRON "IVY-ONE" |
- When using TAKIRON "IVY-ONE", adequately identify the
temperature requirements, type of cleaning solution, irradiation
settings for ultraviolet rays, external stress such as furring,
and other service conditions, and implement proper design and
panel cutting.
- For design and panel cutting, take into consideration the empirical
approaches for fabrication.
- The physical properties, chemical resistances, and other evaluation
data contained in this site are typical test measurement values
and given here without guarantee. Apply the data giving careful
consideration to the actual application and service requirements.
- Keep TAKIRON "IVY-ONE" away from contact with any
plasticizer-containing soft PVC, rubber materials, thinner,or
other materials with the capability to dissolve PVC, to prevent
possible dissolved contact surfaces, roughened surface conditions,
and other defects.
|
| 3 |
Precautions
when fabricating TAKIRON "IVY-ONE" |
- TAKIRON "IVY-ONE" contains PE (polyethylene) protective film attached to
both sides. Remember to remove the protective film prior to construction or
use.
- For fabrication of TAKIRON "IVY-ONE", wear proper gloves, safety goggles,
and other protective equipment as required, and use proper machinery and tools.
- TAKIRON "IVY-ONE" is a PVC product. PVC emits HCl gas when heated. Although
this HCl gas does not attain a concentration that can affect the human body
during normal welding work, HCl gas concentration can vary greatly with working
space and hours, when the work is performed in an enclosed space. In particular,
pay special attention when the work is performed in a confined environment.
For welding processes involving PVC, secure safety by ensuring proper ventilation
on a regular basis, and wearing a proper maskand other protective equipment.
|
| 4 |
Precautions
when storing and transporting TAKIRON "IVY-ONE" |
- TAKIRON "IVY-ONE" can become curved or otherwise deformed when left tilted.
Be sure to place wall panels on a horizontal surface for storage and transportation.
- Remember that masking tape for TAKIRON "IVY-ONE" cannot be completely removed
when they get wet in the rain or with water.
- Avoid storing or transporting TAKIRON "IVY-ONE" and its fabricated products
under direct sunlight or at elevated temperatures.
|
| 5 |
Precautions
when disposing of TAKIRON "IVY-ONE" |
- TAKIRON "IVY-ONE" can emit harmful gases when incinerated. Refer to a designated
industrial waste treatment company for the disposition of waste wall panels
as industrial waste, in accordance with applicable laws and regulations.
|
|
* An FM Label is required to provide evidence that the concerned product is FM
certified, and to ensure traceability in the event of any problem. Remember
to keep FM Labels at hand. |
|