| Item |
Unit |
Opaque |
Transparent |
Test Methods |
FMH
5300 | FMH
5305 | FMHL
5710 Combination with PVC as a Surface and C-PVC as a core material | FMHS
6650 |
| Specific Gravity |
- |
1.75 |
1.55 |
1.63 |
1.46 |
JIS K7112 (MOD ISO 1183) |
| Tensile Stress at Yield |
MPa |
54 |
63 |
55 |
74 |
JIS K 7162-1B/50 (IDT ISO 527-2) |
| Nominal Tensile Strain at Break |
% |
23 |
20 |
22 |
12 |
JIS K 7162-1B/50 (IDT ISO 527-2) |
| Modulus of Elasticity in Tension |
MPa |
3300 |
3000 |
3300 |
3300 |
JIS K 7162-1B/50 (IDT ISO 527-2) |
| Flexural Stress |
MPa |
81 |
88 |
83 |
99 |
JIS K 7171 (IDT ISO 178) |
| Flexural Modulus |
MPa |
3300 |
3000 |
3300 |
3300 |
JIS K 7171 (IDT ISO 178) |
| Chirpy Impact Strength (Notched) |
kj/m2 |
12 |
7.2 |
8.4 |
1.6 |
JIS K 7111-1epA (MOD ISO 179) |
| Vicat Softening Temperature |
°C |
105 |
97 |
Not Application |
94 |
JIS K 7276 (B method) (MOD ISO306) |
| Temperature of Deflection under Load |
°C |
94 |
86 |
85 |
85 |
JIS K 7191 |
| Dimensional Change on Heating (140°C, 55min) |
Longitudinal % |
-3 |
-4 |
-3 |
-5 |
JIS K 7133 (IDT ISO 11501) |
| Latitudinal % |
-2 |
-1 |
-2 |
0.5 |
| Flame Retardant Standards |
FM 4910 |
Listed |
Listed |
Listed |
Listed |
FM4910 |
| |
UL94 |
V-0 |
- |
V-0 |
- |
UL94 |
| Total Light Transmittance |
% |
- |
- |
- |
71 |
JIS K7361-1 |