HOME > Product Information TOP > High Functional Materials Division TOP > STATIC DISSIPATIVE PLATE TOP > Chemical Resistance
Chemical Resistance
The following table shows the behaviors of the Takiron ND Series when in contact with chemicals.
Each chemical was mounted on the specimen for 24 hours.
Surface Resistivity and Appearance were observed after the contact.
Chemical formula Concent-
ration
Electrical Characteristics Appearance
TND ESND FMNDFMND MR PCNDLPETND PETND MRTND ESND FMNDFMND MR PCNDLPETNDPETND MR
HCl36%
20%
H2SO497% NG NGNGNG SC NGNGNGNGNG
60% NGNG
HNO360% NGNG NGNGNG
40% NGNGNG
H3PO485% SC
CH3COOH95% NG
HF46% NGNG
10%
H2O210%
NaOH50% NG NG
(Dissolved)
NGNG
NH4OH25%
Methyl alcohol100%
Ethyl alcohol100% SC
Isopropyl alcohol100%
Buthyl alcohol100% SC
Ethylene glucohol100%
Acetone100% NG NG
(White)
NGNGNGNGNG
Toluene100% NG SC NGNGNGNGNG
NaCl-aquaos30%
Ammonium fluoride50%
KCl10%
Mild detergent10%
Not Affected
SC Slightly Affected
NG Affected
The above test results are a series of our test results for a limited contact period. For longer times and repetitive contact the products may behave differently from the above results.
Our experience indicates that the cleaning of PCND and PCNDL with alcohols does not affect the appearance of the products.